VWR 414005-124 Forced Air Microbiological Incubator

$1,250.00

60-Day Warranty.

The VWR 414005-124 is a 155 L forced-air laboratory incubator with microprocessor temperature control, a stainless steel chamber, and a digital display. Sapas Lab Equipment lists this unit as tested; please contact us for details about the inspection and verified operating functions.

Product Information

Price: $1,250.00
Availability: In Stock
Brand: VWR
SKU: 81
Part Number: —
Operational Status: Tested
Location: Houston, Texas, USA
Ship Weight: —
Warranty: 60-Day Warranty

Request a Personalized Quote

VWR 414005-124 Forced Air Incubator Overview

The VWR 414005-124 incubator is a forced-air laboratory incubator with a 155 L (5.4 cu. ft.) chamber. It uses fan-assisted air circulation and microprocessor-based temperature control to maintain controlled conditions for laboratory workflows. The original VWR operation manual identifies this model as a Forced Air General Incubator.

This model is designed for applications such as animal and plant cell culture, constant-temperature procedures, germination testing, and biochemical oxygen demand (BOD) testing. In addition, its stainless steel chamber and adjustable operating controls support a range of general laboratory incubation requirements.

Explore additional equipment in our Laboratory Incubators category. For model-specific operating instructions, consult the VWR Forced Air General Incubator Operation Manual.

Key Features and Design

  • Forced-air circulation: A fan-assisted system distributes heated air throughout the chamber.
  • Microprocessor temperature control: The controller manages the selected operating temperature.
  • Digital LCD display: The control panel displays operating information and settings.
  • Stainless steel chamber: The interior uses corrosion-resistant 304 stainless steel.
  • Programmable timer: The timer supports operation settings up to 99 hours and 59 minutes.
  • Temperature safety protection: The design includes over-temperature and over-current protection, along with sensor error detection.
  • Computer interface: An RS-232C connection supports remote monitoring and control with a compatible PC configuration.

Technical Specifications

Manufacturer VWR
Model 414005-124
Equipment type Forced-air general laboratory incubator
Chamber capacity 155 L (5.4 cu. ft.)
Power supply 120 V, 60 Hz
Heater rating 400 W
Temperature range Ambient temperature +8°C to 65°C (minimum set value: 25°C), according to the technical specification table
Temperature sensor PT100
Temperature control sensitivity ±0.1°C
Interior material 304 stainless steel
Exterior material Powder-coated steel
Air circulation Forced-air convection
Communication interface RS-232C
Internal dimensions 475 × 550 × 600 mm (18.7 × 21.7 × 23.6 in)
External dimensions 769 × 709 × 906 mm (30.3 × 27.9 × 35.7 in)
Manufacturer-listed net weight 81 kg (179.5 lb)
Location Houston, Texas, USA

Specifications above describe the manufacturer’s model documentation and are not a record of independent performance testing of this individual unit. Confirm the unit’s nameplate, power configuration, and physical dimensions before installation.

Condition and Product Verification

Sapas Lab Equipment lists this incubator as tested and offers it with a 60-day warranty. However, the available listing information does not specify the individual temperature verification results, calibration status, or duration of a temperature stability test. Therefore, buyers should request details about the inspection and the functions verified on this particular unit.

Before placing an order, confirm the condition of the chamber, door, seals, controller, fan, heating system, shelves, and electrical connection. Likewise, verify that the unit reaches and maintains the temperature required for your application.

Included Equipment and Components

The product listing identifies one VWR 414005-124 forced-air incubator. The original VWR manual lists the following items in the standard package for this model family:

  • Forced-air incubator
  • Power cord
  • Stainless steel shelves
  • Stainless steel shelf rails
  • Operation manual
  • Warranty card

These items describe the original manufacturer’s package contents; they do not confirm that every item accompanies this used unit. Please check the product photographs or contact Sapas Lab Equipment to verify the actual included shelves, rails, power cord, and documentation before purchase.

Applications and Buyer Considerations

The manufacturer’s manual identifies animal and plant cell culture, constant-temperature procedures, germination tests, and BOD testing as intended applications. Consequently, this incubator may be relevant to research laboratories, educational institutions, and other facilities requiring controlled-temperature incubation.

However, buyers should evaluate the documented temperature range and verify the unit’s actual operating performance before using it for temperature-sensitive procedures. Also, confirm that the 120 V, 60 Hz configuration matches the electrical supply at the installation site.

For further technical information, review the VWR 414005-124 technical specifications.

Additional Benefits

  • Local pickup available in Houston, Texas.
  • Free shipping on select products within the USA; shipping charges may apply to this item.
  • International shipping via FedEx available upon request and quotation.
  • 60-day warranty.

Contact Sapas Lab Equipment today to request a quote for the VWR 414005-124 forced-air incubator. Our team can help confirm the unit’s condition, included components, shipping options, and compatibility with your laboratory requirements.

Weight 195 lbs
Dimensions 34 × 30 × 42 in

Reviews

There are no reviews yet.

Be the first to review “VWR 414005-124 Forced Air Microbiological Incubator”